List of Electrical Activities which are executed generally at site on Electrical/ELV projects

 

List of Electrical Activities which are executed generally at site on Electrical/ELV projects

Sl.No:

Activity

Installation covered

Unit

Remark

No.of hours

No.of person

Manhours

 

 

 

 

 

 

 

 

1

PVC Conduiting (20,25,32mm dia) / point

Lighting, LCP, CBS, Small power, Equipment power

Meter

Rate differs based on the access availability

0.5

3

2

2

PVC Conduiting (> 38 mm dia) / point

Lighting, LCP, CBS, Small power, Equipment power

Meter

0.5

3

2

3

G.I Conduiting (20,25,32mm dia) / point

Lighting, LCP, CBS, Small power, Equipment power

Meter

1

4

4

4

uPVC ducting for sleeves

Power distribution for Small power, Equipment power & ELV services

Meter

0.5

2

1

5

Cable tray (<225 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

Rate differs based on the fitting available (i.e. Ready made or Custom fabrication)

1

4

4

6

Cable tray (>225 & <450 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

1

4

4

7

Cable tray (450 & 600 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

1

4

4

8

Cable tray (>600 & <800 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

1.5

4

6

9

Cable tray (>800 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

1.5

4

6

10

Cable trunking (<225 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

2

4

8

11

Cable trunking (>225 & <450 mm wide)

Power distribution for Small power, Equipment power & ELV services

Meter

1

4

4

12

Cable ladder (>450 & <600 mm wide)

Power distribution for Small power, Equipment power & ELV services

No.

 

1

4

4

13

Cable ladder (>600 & <900 mm wide)

Power distribution for Small power, Equipment power & ELV services

No.

 

1.5

4

6

14

DB Installation (4 to 8 way)

Installation & Termination

No.

 

8

4

32

15

DB Installation (10 to 14 way)

Installation & Termination

No.

 

14

4

56

16

DB Installation (>16 way)

Installation & Termination

No.

 

16

4

64

17

SMDB Installation (4 to 8 way)

Installation, Glanding & Termination

No.

 

19

4

76

18

SMDB Installation (10 to 14 way)

Installation, Glanding & Termination

No.

 

24

4

96

19

MSB Installation (4 to 8 way)

Installation, Glanding & Termination

No.

 

22

5

##

20

MCC Panel Installation

Installation, Glanding & Termination

No.

 

16

4

64

21

LV panel installation

Installation, Glanding & Termination

No.

 

48

6

##

22

Transformer Installation

Installation, Glanding & Termination

No.

 

80

6

##

23

UPS -1 PH & 3 PH (< 10kVA)

Installation, Glanding & Termination

No.

 

10

3

30

24

UPS -1 PH & 3 PH (>10kVA & < 20kVA)

Installation, Glanding & Termination

No.

 

10

4

40

25

UPS -1 PH & 3 PH (>20kVA & < 40kVA)

Installation, Glanding & Termination

No.

 

14

5

70

26

UPS -1 PH & 3 PH (>40kVA & < 60kVA)

Installation, Glanding & Termination

No.

 

24

5

##

27

UPS -1 PH & 3 PH (>60kVA & higher)

Installation, Glanding & Termination

No.

 

24

5

##

28

Lighting Control panel

Installation, Glanding & Termination

No.

 

8

4

32

29

Central Battery system panels

Installation, Glanding & Termination

No.

 

8

4

32

30

Main CBS panel with battery rack

Installation, Glanding & Termination

No.

 

32

5

##

31

Armoured cables - 3C/4C x 2.5 - 6 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

3

3

32

Armoured cables - 3C/4C x 10 - 16 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

4

4

33

Armoured cables - 3C/4C x 25 - 35 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

5

5

34

Armoured cables - 3C/4C x 50 - 95 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1.5

6

9

35

Armoured cables - 3C/4C x 120 - 150 sq.mm

Cable pulling, Glanding & Termination

Meter

 

2

6

12

36

Armoured cables - 3C/4C x 185 - 240 sq.mm

Cable pulling, Glanding & Termination

Meter

 

2.5

6

15

37

Armoured cables - 3C/4C x 300 - 400 sq.mm

Cable pulling, Glanding & Termination

Meter

 

3

6

18

38

Armoured cables - 1C x 800 sq.mm

Cable pulling, Glanding & Termination

Meter

 

5

8

40

39

Earth cables - 1C x 2.5 - 6 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

3

3

40

Earth cables - 1C x 10 - 16 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

4

4

41

Earth cables - 1C x 25 - 35 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1

4

4

42

Earth cables - 1C x 50 - 95 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1.5

4

6

43

Earth cables - 1C x 120 - 150 sq.mm

Cable pulling, Glanding & Termination

Meter

 

1.5

5

8

44

Earth cables - 1C x 185 - 240 sq.mm

Cable pulling, Glanding & Termination

Meter

 

2

5

10

45

Earth cables - 1C x 300 - 400 sq.mm

Cable pulling, Glanding & Termination

Meter

 

2

6

12

46

Earth cables - 1C x 400 sq.mm

Cable pulling, Glanding & Termination

Meter

 

2

6

12

47

Single core PVC wiring for lighting point

PVC wiring

Meter

 

1

4

4

48

FP200 wiring for emergency lighting point

FP200 wiring

Meter

 

1

4

4

49

Ceiling rose installation

Installation & Termination

No.

 

1

2

2

50

Dismantle - Spot light & Down light

Dismantling & Relocation with same material

No.

 

1.5

2

3

51

Dismantle - 60x 60mm

Dismantling & Relocation with same material

No.

 

1.5

2

3

52

Dismantle - LED cove, linear strip

Dismantling & Relocation with same material

Meter

 

1.5

2

3

53

Dismantle - Pendant

Dismantling & Relocation with same material

No.

 

2

2

4

54

Dismantle - Pole mounted

Dismantling & Relocation with same material

No.

 

2

2

4

55

Dismantle - Chandlier

Dismantling & Relocation with same material

No.

 

6

4

24

56

Dismantle - Switches, Sockets & Outlets

Dismantling & Relocation with same material

No.

 

2

2

4

57

Dismantle - Isolators

Dismantling & Relocation with same material

No.

 

4

2

8

58

Dismantle - Floor box

Dismantling & Relocation with same material

No.

 

2

2

4

59

Dismantle - Floor trunking

Dismantling & Relocation with same material

Meter

 

2

2

4

60

Light fixtures - Spot

Installation & Termination with driver

No.

 

1

2

2

61

Light fixtures - Down

Installation & Termination with driver

No.

 

1

2

2

62

Light fixtures - 60 x 60mm

Installation & Termination with driver

No.

 

1

2

2

63

Light fixtures - LED Cove

Installation & Termination with driver

Meter

 

1

2

2

64

Light fixtures - Linear recessed strip

Installation & Termination with driver

Meter

 

1

2

2

65

Light fixtures - Linear surface mounting

Installation & Termination with driver

No.

 

1

2

2

66

Light fixtures - Pendant light

Installation & Termination with driver

No.

 

1

2

2

67

Light fixtures - Wall Mounted

Installation & Termination with driver

No.

 

1

2

2

68

Light fixtures - Pole Mounted

Installation & Termination with driver

No.

 

1

2

2

69

Light fixtures - Chandlier

Installation & Termination with driver

No.

 

4

4

16

70

Light fixtures - Special Custom made

Installation & Termination with driver

No.

 

2

2

4

71

Light fixtures - EXIT (Wall & ceiling mounted)

Installation & Termination with driver/modules & batteries

No.

 

1

2

2

72

Light fixtures - Emergency (Wall & ceiling mounted)

Installation & Termination with driver/modules & batteries

No.

 

1

2

2

73

Presence Sensor

Installation & Termination

No.

 

0.5

2

1

74

Day light Sensor

Installation & Termination

No.

 

0.5

2

1

75

Switches - 1G, 2G, 3G & Multigang normal

Installation & Termination

No.

 

1.5

2

3

76

Switches - 1G, 2G, 3G & Multigang Grid

Installation & Termination

No.

 

1.5

2

3

77

Switches - 1G, 2G, 3G & Multigang Dimmer

Installation & Termination

No.

 

1.5

2

3

78

Switches - 1G, 2G, 3G & Multigang Push button

Installation & Termination

No.

 

1.5

2

3

79

Sockets - 1G, 2G normal

Installation & Termination

No.

 

1.5

2

3

80

Sockets - 1G, 2G Weather Proof

Installation & Termination

No.

 

1.5

2

3

81

DP, Spur units, Flex outlet etc.

Installation & Termination

No.

 

1.5

2

3

82

Floor Box

Installation & Termination

No.

 

2

2

4

83

Industrial sockets - 1 & 3 Phase

Installation & Termination

No.

 

1

2

2

84

Isolators - 1 & 3 Phase (On wall / slab)

Installation, Glanding & Termination

No.

 

2

2

4

85

Isolators - 1 & 3 Phase (On pedestrail)

Installation, Glanding & Termination

No.

 

3

2

6

86

Dismantle - FACP, MIMIC, Zone Chart, Evac. Panel

Dismantling & Relocation with same material

No.

 

10

3

30

87

Dismantle - SD, HD, MSD, LED indicator

Dismantling & Relocation with same material

No.

 

2

2

4

88

Dismantle - Pull station, Sounder, Modules

Dismantling & Relocation with same material

No.

 

2

2

4

89

Fire Alarm Panel Installation

Installation, Glanding & Termination

No.

 

8

3

24

90

Evacuation control panel Installation

Installation, Glanding & Termination

No.

 

8

3

24

91

MIMIC panel installation

Installation, Glanding & Termination

No.

 

8

3

24

92

Zone Chart installation

Installation, Glanding & Termination

No.

 

8

3

24

93

Smoke /Heat / Multi sensor detector

Installation, Glanding & Termination & Addressing

No.

 

1

2

2

94

LED indicator

Installation, Glanding & Termination & Addressing

No.

 

0.5

2

1

95

Pull station

Installation, Glanding & Termination & Addressing

No.

 

1

2

2

96

Sounder

Installation, Glanding & Termination & Addressing

No.

 

1

2

2

97

Module - Monitor/Control & I/O

Installation, Glanding & Termination & Addressing

No.

 

1

2

2

98

FP200 2C x 1.5 Sq.mm for FA devices

Cable pulling only

No.

 

1

2

2

99

FP200 2C x 2.5 Sq.mm for Sounder

Cable pulling only

No.

 

1

2

2

100

Containment for FA devices with 25mm dia conduit

Conduiting only

No.

 

1

4

4

101

Dismantle - IT- IDF rack wall mounted

Dismantling & Relocation with same material

No.

 

10

3

30

102

Dismantle - IT- IDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

3

30

103

Dismantle - IT- MDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

5

50

104

Dismantle - Data/Tel.outlet

Dismantling & Relocation with same material

No.

 

2

2

4

105

Dismantle - WAP

Dismantling & Relocation with same material

No.

 

2

2

4

106

MDF rack for IT

Panel / Enclosure Installation only

No.

 

6

5

30

107

IDF rack for IT

Panel / Enclosure Installation only

No.

 

4

3

12

108

FOC cabling for IDF & MDF

Cable pulling only

Meter

 

1

3

3

109

Cat 6A cabling for data & tel. point

Cable pulling only

Meter

 

1

3

3

110

Containment for IT devices with 25mm dia conduit

Conduiting only

Meter

 

0.5

3

2

111

Data / Tel. / WAP outlet installation

Outlet fixing, termination & testing by TPI System specialist

No.

 

1

2

2

112

Dismantle - CCTV- IDF rack wall mounted

Dismantling & Relocation with same material

No.

 

10

3

30

113

Dismantle - CCTV- IDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

3

30

114

Dismantle - CCTV- MDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

5

50

115

Dismantle - CCTV outlet

Dismantling & Relocation with same material

No.

 

2

2

4

116

Dismantle - CCTV Cameras

Dismantling & Relocation with same material

No.

 

2

2

4

117

MDF rack for CCTV

Panel / Enclosure Installation only

No.

 

8

6

48

118

IDF rack for CCTV

Panel / Enclosure Installation only

No.

 

8

4

32

119

FOC cabling for IDF & MDF

Cable pulling only

Meter

 

1

3

3

120

Cat 6A cabling for CCTV point

Cable pulling only

Meter

 

1

3

3

121

Containment for CCTV devices with 25mm dia conduit

Conduiting only

Meter

 

0.5

3

2

122

CCTV outlet installation

Outlet fixing, termination & testing by TPI System specialist

No.

 

1

2

2

123

CCTV camera installation

Installation, termination & testing by TPI System specialist

No.

 

1.5

2

3

124

Dismantle - ACS- IDF rack wall mounted

Dismantling & Relocation with same material

No.

 

10

3

30

125

Dismantle - ACS- IDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

3

30

126

Dismantle - ACS- MDF rack floor mounted

Dismantling & Relocation with same material

No.

 

10

5

50

127

Dismantle - ACS outlet

Dismantling & Relocation with same material

No.

 

2

2

4

128

Dismantle - ACS  Field Devices

Dismantling & Relocation with same material

No.

 

2

2

4

129

MDF rack for ACS

Panel / Enclosure Installation only

No.

 

8

6

48

130

IDF rack for ACS

Panel / Enclosure Installation only

No.

 

8

4

32

131

FOC cabling for IDF & MDF

Cable pulling only

Meter

 

1

3

3

132

Cat 6A cabling for ACS point

Cable pulling only

Meter

 

1

3

3

133

Containment for ACS devices with 25mm dia conduit

Conduiting only

Meter

 

0.5

3

2

134

ACS Field Device installation

Outlet fixing, termination & testing by TPI System specialist

No.

 

0.5

2

1

135

Dismantle - PA rack wall mounted

Dismantling & Relocation with same material

No.

 

10

3

30

136

Dismantle - PA rack floor mounted

Dismantling & Relocation with same material

No.

 

10

3

30

137

Dismantle - PA speakers

Dismantling & Relocation with same material

No.

 

2

2

4

138

PA rack wall mounted

Panel / Enclosure Installation only

No.

 

8

4

32

139

PA rack floor mounted

Panel / Enclosure Installation only

No.

 

8

4

32

140

PA speakers point

Cable pulling only

Meter

 

1

3

3

141

Containment for PA devices with 25mm dia conduit

Conduiting only

Meter

 

1

4

4

142

PA speakers device installation

Installation, termination by NEC & testing by TPI System specialist

No.

 

1

2

2

143

Dismantle - DAS rack wall mounted

Dismantling & Relocation with same material

No.

 

10

4

40

144

Dismantle - DAS field Devices

Dismantling & Relocation with same material

No.

 

2

2

4

145

DAS rack wall mounted

Panel / Enclosure Installation only

No.

 

8

3

24

146

Containment for DAS devices with 25mm dia conduit

Conduiting only

No.

 

0.5

3

2

147

DAS Field Devices point wiring

Cable pulling only

No.

 

1

3

3

148

DAS Field Devices

Installation, termination by Contractor & testing by TPI System specialist

No.

 

1.5

2

3

149

DDC Panels

Installation, termination by Contractor & testing by TPI System specialist

No.

 

24

3

72

150

DDC works station

Installation, termination by Contractor & testing by TPI System specialist

No.

 

8

3

24

151

BMS field sensors

Installation, termination by Contractor & testing by TPI System specialist

No.

 

2

2

4

 

Post a Comment